POW003 : มิเตอร์วัดหน่วยไฟฟ้า มิเตอร์วัดกำลังไฟฟ้า เพาเวอร์มิเตอร์ RS485 3-Phase Power Energy Meter 4-digit Electric Current Voltage VA Hz kWh YG889-9SY

มิเตอร์วัดหน่วยไฟฟ้า มิเตอร์วัดกำลังไฟฟ้า เพาเวอร์มิเตอร์ RS485 3-Phase Power Energy Meter 4-digit Electric Current Voltage VA Hz kWh YG889-9SY

>> เช็คสต๊อคสินค้า <<

รายละเอียดสินค้า Multi-function power meter has measurement, display, digital communication and electrical pulse output functions. It is able to accomplish power measurement, energy metering, data display, collection and transmission, and can be widely used for transformer substation, power distribution, intelligent building, company. It can measure current, voltage, active power, reactive power, apparent power, power factor, frequency, active energy, reactive energy, inductive capacitive energy, positive and negative reactive power. Features:
  • The power meter is easy to operate, safe, accurate, durable, intelligent, and energy saving.
  • Housing is made of flame retardant ABS material, the structure is more secure.
  • Plug type connectors are more convenient to wire.
  • Designed with many heat dissipation holes on the back for more safe use.
  • High quality blue backlight LCD screen offers a high-definition display on day or night.
  • Support RS485 communication.
  Specifications:
Accuracy Voltage/Current:0.5%, 0.2%;Frequency:0.1%;Power,Power Factor:0.5%
Display 4-digit 
Input Nominal Current AC5A
Voltage AC380V
Overload Continuous: 1.2times; Instantaneous: voltage 2times(10sec.), current 10times(5sec.)
Frequency 50/60Hz±10%
Power Supply Auxiliary Power Supply AC220V±5%
Power Consumption <3VA
Dielectric Strength AC2kV
Insulation Resistance ≥100MΩ
Average Lifespan ≥50,000h
Working Environment Temperature: -10~55;Relative Humidity:≤93%; No corrosive gas; Altitude:≤2500m
  Note: 
  1. The meter should be connected to power for 15 minutes before use.
  2. Protect it against vibration or impact and do not use it in environment of much dust or noxious gas.
  3. Input wire should not be too long. If measured signal input terminal is too long, please try using twisted-pair shielded wire.
  4. If signal has high frequency interference, low frequency filter should be tried using in wire.
  5. During long-term storage, please connect it to power for at least 4 hours once every three months.
  6. For long-term storage, it should be kept in temperature - 25 ~ 55 and away from direct light.
  7. If meter does not display, please first check  if the voltage of auxiliary power supply is in the normal range.
  8. If meter displays abnormally, please check if the input signal is normal and signal terminal are connected tightly.
  9. Do not use PT signals as auxiliary power, in order to guarantee he meter can normally work, unless the PT has enough power.
  10. Terminals of CT circuits must be connected tightly, ensuring reliable input/output contact.
  11. If need to calibrate meter, use calibration instrument which has accuracy better than 0.1%.
Package Includes: